LMS PT 18-2 GIN POLE
LMS PT 18-2 Gin Pole manufacturing, servicing, inspections, and repairs we are the primary source for these services for all of the Americas since 2011. We manufacture the finest Gin Poles in the world with a 100% safety rating worldwide, LMS Gin Poles are manufactured with steel or aluminum in all sizes. Custom models build for elevator transport for rooftop antennas and towers. Poles are built are round poles, (GP) triangle poles, (PT), and square poles with jump tracks, (PS). Our poles are Electrostatic coated for long life and ease of handling and safety. You can also find Landa Mobile Systems towers HERE You can also find other LMS news HERE
Manufactured to ANSI/TIA-322
- AWS Certified
- U.S. AWS Certified welder assembled
- U.S. Certified Gin Pole AWS welder assembled
- Certified AWS independent contractor inspected
- AWS D1.1:2015 Structural welding code-steel
- Load charts are pole specific with matching serial numbers
- 5.0 Analysis and design of Gin Poles
- 6.0 Gin Pole construction
- Metalized surface
- Base end roller end
- Double sheave rooster head
- Guy tower base end
- X Braced top and bottom section
- 2″ legged pole for heavier picks
OSHA required Forms, supplied with all LMS gin poles we manufacture.
- Annual Pole Certification signed and numbered
- Annual Pole Inspection Report signed and numbered
- VT Visual Welding Inspection Report, done at the time of manufacture
- Mill Report on steel specification ASTM A500, Grade B/C
- Charpy report on steel temperature test to –40 degrees
- PE Stamped Pole specific Load Chart
Weights 64′ Pole
- TBD 65Lb / 29Kg Head section
- TBD 350Lb / 159Kg 20′ Sections
- TBD 110Lb / 50Kg Tail section
- TBD 87Lb / 39Kg Rooster head and bearing
- TBD 1450Lb / 658Kg Shipping weight
LMS PT 18 Sheave options
LMS PT 18 Sheave 7/16″
LMS PT 18 Gin Pole Sheave 7/16, OEM replacement 7/16″ groove, 8″ diameter
LMS PT 18 Sheave 5/8″
LMS PT 18 Gin Pole Sheave 5/8″, OEM replacement 5/8″ groove, 8″ diameter
LMS PT 18 Sheave 3/8′
LMS PT 18 Gin Pole Sheave 3/8, OEM replacement 7/16″ groove, 8″ diameter
Gin Pole Classifications
Class | Gross Loading | Load Line Size | Impact Factor Req’d steel wire rope |
A | 0 < 1,000 Lbs | d<= 5/16″ | 1.45 |
B | 1,000 < 3,000 Lbs | 5/16″ < d <= 7/16″ | 1.35 |
C | 3,000 < 10,000 Lbs | 7/16″ < d <= 9/16″ | 1.25 |
D | 10,000 + Lbs | d > 9/16″ | 1.20 |
We do not supply any accessory hardware or assembly bolts. Use 3/4″×2.5″ A325 Structure bolts, washers and nuts only. Remember to inspect before re-using.
OPTIONAL SST (CHICAGO STYLE) ROLLER END
ROOSTER HEAD OPTION
Complete records of pole inspections and record of Magnetic particle inspection shall be performed on 10% of the welded connections every 10 years. Annual inspections reports shall be maintained for a minimum of two years. All gin pole operations must be in compliance with the latest revision of ANSI/TIA-322 and the OSHA CPL 2-1.36, Maintain your required documents along with work plan, engineer sign off for each specific job.